TM  55-1520-240-23-5
6-79
DISASSEMBLE  AFT TRANSMISSION SUMP
(Continued)
6-79
4.
Turn  sump  (10)  over 180º.   Remove  lockwire
from  drain  valve  (11).  Remove  drain  valve  and
packing  (12).
5.
Remove  detection  screen  and  chip  detector (13)
as  follows:
a.
Push  in  cap  (14),  twist  to  left,  and  pull  to
remove  cap  and  packing  (15).
b.
Remove  lockwire  from  three  bolts  (16).
Remove  bolts  and  washers (17).
c.
Remove  housing  (18)  and  packing  (19).
6.
Remove  lockwire  from  temperature  probe  (20).
Remove  temperature  probe  and  packing  (21).
FOLLOW-ON MAINTENANCE:
None
END  OF  TASK
6-305