TM 55-1520-240-23-5
6-80
ASSEMBLE AFT TRANSMISSION SUMP
(Continued)
6-80
INSPECT
10.
Turn sump (3) over 180º.
Do not use more than 30 psi
compressed air for cleaning. Debris
propelled under pressure can
cause injury to eyes. Use source of
compressed air under 30 psi and
eye protection to prevent injury to
personnel.
NOTE
If screen is new, cleaning is not
needed.
11.
Clean inlet screen (12) with dry cleaning solvent
(E162) and cloths (E120). Dry screen with
compressed air. Wear gloves (E186) and
goggles.
12.
Install gasket seal (13) and inlet screen (12) on
eight studs (14). Install eight washers (15) and
nuts (16). Torque nuts to 20 inch-pounds.
13.
Install screen cap (17) on six studs (18). Install
six washers (19) and nuts (20). Torque nuts to
20 inch-pounds.
14.
Install two packings (21) on transfer tube (22).
Install transfer tube in sump (3).
15.
Install two packings (23) on transfer tube (24).
Install transfer tube in sump (3).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK