TM 55-1520-240-23-5
6-75
REMOVE COMBINING TRANSMISSION FROM STORAGE (Continued)
6-75
9.
Remove all tape and barrier material from
transmission (10).
WARNING
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
CAUTION
Touching splines with bare fingers can
cause corrosion.
10.
Remove corrosion-preventive compound from
forward output shaft splines (14), aft output shaft
splines (15), input shaft splines (16) and four
bushings (17). Use dry cleaning solvent (E162)
and clean cloth (E120). Wear goggles (E473)
and gloves (E186).
11.
Drain residual oil from each of three
compartments of sump (18) as follows:
a.
Install hose on drain valve (19 or 20). Push
in drain valve, twist it, and pull. Let oil drain
into container.
b.
Push in valve (19 or 20), twist it, and pull to
close.
INSPECT
FOLLOW-ON MAINTENANCE:
Assemble combining transmission (Task 6-76).
END OF TASK
Change 1