TM 55-1520-240-23-10
16-7.1.1
TEST CENTER CARGO HOOK (AVIM)
16-7.1.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Hydraulic Test Stand
DC Power Supply, 0 to 50 Volts
Multimeter
Stopwatch
Hoist, 300 Pound Capacity
Weight, 20 Pound
Wire Rope Ring (APP E-18)
Dial Indicating Scale, 0 to 50 Pounds
Materials:
None
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
Task 16-3 Without 35
Task 16-3.1 With 35
Task 16-5 Without 35
Task 16-5.1 With 35
Task 16-7 Without 35
Task 16-7.1 With 35
Task 16-7.2
APP E
Equipment Condition:
Off Helicopter Task
Actuator Serviced to 2,100 psi (Task 1-74)
General Safety Instructions:
Stand clear of hook and load when
raising, lowering, or releasing load to
prevent injury to personnel.
Use suitable crash box to shield
personnel and equipment in case of
failure during test.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
16-67