TM  55-1520-240-23-9 11-176 ADJUST ROLL OR YAW CONTROL POSITION TRANSDUCER (CPT) (Continued) 11-176 4. Have  helper  release  switch  (1)  of  stick  (2). 5. Set MASTER  POWER  switches  (15  and  16) of line  test  set  (17)  to  ON. 6. Set  METER  SOURCE  switch  (18)  to  CPT MONITOR. ADJUST ROLL  CPT 7. Set CPT  MONITOR  switch  (19) to  LATERAL. 8. Check  digital display (20).  Display must  indicate between  -0.050 to +0.050 vac.   If indication  is within  limits, go  to  step  12.  If  not, perform  steps 9  thru  11,  then  go  to  step  12. 9. Remove  lockwire  from  lockwasher (21)  and  nut (22) of  roll  position  transducer (23).  Loosen  nut. 10. Turn  outer  shell  (24) of  transducer  (23)  until display (20) indicates between  -0.050  to +0.050 vac. 11. Align  lockwasher  (21)  and  tighten  nut  (22). Lockwire  nut to lockwasher.  Use  lockwire  (E231). 11-699