TM  55-1520-240-23-9 11-84 INSTALL  STICK  PITCH  POSITION INDICATOR (Continued) 11-84 24. Clean sealant from  flange (56) and  inside  surface (57)  of  access.   Use  acetone  (E20)  and  cloths (E120).  Wear  gloves (E186)  and  goggles. Wires  must  not  support  housing; otherwise,  damage  to  equipment could  occur. 25. Support housing  (58).  Remove  strap  (59). 26. Apply sealant (E336) to  both  sides of gasket (60). Install  gasket  on  flange  (56).   Remove  excess sealant  with  acetone  (E20)  and  cloths (E120). Use  goggles  for  eyes. 27. Tilt  housing  assembly  (58)  and  position  up  and inside  access (37),  lamp  (61)  aft.  Align  housing and  access  holes  (62). 28. Position  housing  (63)  over  access  (37).  Install  32 washers  (64)  and  screws  (65). INSPECT FOLLOW-ON  MAINTENANCE: Install  AFCS  panel  (Task 11-273). Install  ADF  RCVR  panel  (TM  11-1520-240-20). Perform  operational  check  of  landing  light  (TM 55-1520-240-T). END  OF  TASK 11-446