TM  55-1520-240-23-9 11-84 INSTALL  STICK  PITCH  POSITION  INDICATOR 11-84 INITIAL  SETUP Applicable  Configurations: All Tools: Aircraft Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Torque  Wrench,  5  to  50  Inch-Pounds Dial Indicating  Scale, 0  to  10  Pounds Materials: Acetone  (E20) Cloths  (E120) Sealant  (E336) Lockwire  (E231) Gloves  (E186) Parts: Gasket Cotter  Pin Personnel  Required: Medium  Helicopter Repairer (2) Inspector References: TM  55-1520-240-23P Task  11-45 General  Safety Instructions: Sealant  (E336) can  irritate  skin  and cause  burns.  Avoid  contact  with  skin, eyes,  and  clothing.  In  case  of  contact, immediately  flush  skin  or eyes  with water for  at  least  15 minutes.   Get medical  attention  for eyes. Acetone  (E20)  can  form  toxic vapors  if  exposed  to  flame.   Use  in well-ventilated  area,  away from  open flame.  In  case  of contact,  immediately flush  skin  or  eyes  with  water  for at  least  15  minutes.   Get  medical attention  for eyes. 11-442