TM  55-1520-240-23-9 11-277 BENCH  TEST AFCS  COMPUTER  (AVIM) (Continued) 11-277 TEST  5 ROLL  AXIS  TEST NOTE Perform  preliminary  procedure  before test.  (Refer  to  TM 55-4920-430-13.) 168. Set METER  switch  (6)  to  DC. 169. Set METER  RANGE  switch  (7)  to  20V. 170. Set CIRCUIT  SELECT  A/B  SELECT  switch  (9) to  A. 171. Set CIRCUIT  SELECT TENS  switch  (8)  to  10. 172. Set CIRCUIT  SELECT  A  UNITS  switch  18  to  3. 173. Set  RESPONSE  TEST  TIME  DELAY-SEC switches  (40)  to  0.05. 174. Set RESPONSE TEST  MODE  switch  (43)  to  ON. 175. Set  ANALOG  SIGNALS  ATT  SELECT  switch (37)  to  ROLL. 176. Set ANALOG SIGNALS ATT synchro (38)  to  2.5º. 177. Set  RESPONSE  TEST  STIM  switch  (44)  to APPLY. When  HOLD  lamp  (45)  comes on,  read AC/DC  VOLTMETER  (10).   Reading  shall  be +2.83 to +4.07. 178. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 179. Set  RESPONSE  TEST  TIME  DELAY-SEC switches  (40)  to  0.11. 180. Set  RESPONSE  TEST  STIM  switch  (44)  to APPLY. When  HOLD  lamp  (45)  comes on,  read AC/DC  VOLTMETER  (10).   Reading  shall  be +1.59 to +2.29. 11-1088