  1064    1065    1066    1067    1068  1069  1070    1071    1072    1073    1074  
TM  55-1520-240-23-9 11-277 BENCH TEST AFCS  COMPUTER  (AVIM) (Continued) 11-277 135. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 136. Set  RESPONSE  TEST  TIME  DELAY-SEC switches  (40)  to  10.0.   Wait 60 seconds. 137. Set  RESPONSE  TEST  STIM  switch  (44)  to APPLY. When  HOLD  lamp  (45)  comes  on,  read AC/DC  VOLTMETER  (10).   Reading  shall  be +3.08 to +4.44. 138. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 139. Set  RESPONSE  TEST  MODE  switch  (43)  to OFF. 140. Set ANALOG  SIGNALS PITCH  RATE switch  (46) to  1.   Wait  60 seconds. 141. Set  CIRCUIT  SELECT  A  UNITS  switch  (18) to  9.   Read  and  record  V1  reading  on  AC/DC VOLTMETER  (10). 142. Set  ANALOG  SIGNALS  ATT  SELECT  switch (37)  to  ROLL. 143. Set ANALOG  SIGNALS  YAW  RATE  switch  (34) to  4. 144. Set  ANALOG  SIGNALS  ATT  synchro  (38)  to 45º.   Read  and  record  V2  reading  on  AC/DC VOLTMETER  (10). 145. Calculate  V3.  Subtract  reading  in  step  141  from reading  in  step  144  (V3  =  V2  -V1).   Result shall be  +2.16 to +3.02  volts. 11-1085