TM  55-1520-240-23-9 11-277 BENCH  TEST AFCS  COMPUTER  (AVIM) (Continued) 11-277 194. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 195. Set ANALOG  SIGNALS  ROLL  RATE  switch  (30) to  2. 196. Set ANALOG  SIGNALS  LAT  CPT  switch  (29) to  2. 197. Set  RESPONSE  TEST  TIME  DELAY-SEC switches  (40)  to  1.5. 198. Set  RESPONSE  TEST  STIM  switch  (44)  to APPLY.  When  HOLD  lamp  (45)  comes on,  read and  record  V4 AC/DC  VOLTMETER (10) reading. 199. Calculate  V5.  Subtract reading  of step  187  from reading  of step  198  (V5  =  V4  -  V1).  Result  shall be  -5.76  to  -8.29  volts. 200. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 201. Set  RESPONSE  TEST  TIME  DELAY-SEC switches  (40)  to  4.0.  Wait  60  seconds. 202. Set  RESPONSE  TEST  STIM  switch  (44)  to APPLY.  When  HOLD  lamp  (45)  comes on,  read and  record  V6 AC/DC  VOLTMETER (10) reading. 203. Calculate  V7.  Subtract reading  of step  187  from reading  of step  202  (V7  =  V6  -  V1).  Result  shall be  -3.52  to  -5.06  volts. 204. Set  RESPONSE  TEST  STIM  switch  (44)  to REMOVE. 205. Set ANALOG  SIGNALS  LAT  CPT  switch  (29) to  3. 206. Set ANALOG  SIGNALS  ROLL  ATT  switch  (50) to  2. 11-1090