TM 55-1520-240-23-8
10-22
TEST MAIN FUEL TANK AFTER INSTALLATION
(Continued)
10-22
b.
Check forward breakaway fittings (15, 16 and
17), manifold (18), tee (19), and two elbows
(20). Apply soap mixture as in step 15a.
Secure fittings, manifold, or elbows. Replace
packings, if needed. If leak is found, repeat
steps 13 and 14.
c.
Check filler adapter (21). Apply soap mixture
as in step 15a. Secure filler adapter, or
replace packing if needed. If leak is found,
repeat steps 13 and 14.
10-95