TM  55-1520-240-23-8 10-22 TEST MAIN  FUEL  TANK AFTER  INSTALLATION (Continued) 10-22 21. Open vent valve  (4) and reduce pressure to 0 psi. 22. Disconnect test  setup  B  from  fitting  (12). 23. Install  conical  seal  (12.1)  in  hose  fitting  (12). Hold  fitting  with  wrench  and  connect  hose  (13). 24. Remove  cap  from  fitting  (1) and  plug  from  hose (2).  Install  conical  seal  (2.1)  in  hose  (2) fitting. Hold  fitting  with  wrench  and  connect hose. 10-99