REMOVE  FORWARD  FUEL  TANK

TM-55-1520-240-23-8 CH-47D Heilcopter Manual
Page Navigation
  92    93    94    95    96  97  98    99    100    101    102  
TM  55-1520-240-23-8 10-22 TEST  MAIN  FUEL TANK AFTER  INSTALLATION (Continued) 10-22 25. Remove  plug  from port  (11).  Install  two  packings (9  and  10)  on  valve  (8).  Install  valve  in  port (Task 10-40). 26. Remove  cap  from  fitting  (6)  and  plug  from  hose (7).  Hold  fitting  with  wrench  and  connect  hose. INSPECT FOLLOW-ON  MAINTENANCE: Perform  vent  system  flow  test  (Task  10-118)  on affected  tank. Perform  test  of  pressure  refueling  system  (Task 10-119)  and  fuel  feed  system  (Task  10-120). Refuel  main  tank (Task  1-51). Check  for  leaks  (Task  10-4). Bleed  fuel  system  (Task 10-121). Perform  operational  check  of affected  fuel  system (TM  55-1520-240-T). Close  forward  landing  gear  access panel  (Task 2-2). Close  aft intertank  pod  panel (Task  2-188). END  OF  TASK 10-100