TM  55-1520-240-23-8 10-22 TEST  MAIN  FUEL TANK AFTER  INSTALLATION (Continued) 10-22 11. Hold  fitting  (12)  with  wrench  and  disconnect hose  (13).  Remove  conical  seal  (12.1)  from  hose fitting  (12.2). TEST SETUP  B 12. Connect  test setup  B  to  fitting  (12). Do  not allow  pressure  to  exceed  5.0 psi.  Damage  to  helicopter  will  occur. 13. Open  valve  (3)  and  allow  pressure  to  stabilize at 2  to 4 psi.   Close  valve.   Record  gage  (14) indications. 14. Wait  15  minutes.   Check  gage.   If  there  is  no change  in  pressure,  go  to  step  21.   If  pressure has  dropped,  go  to  step  16. CHECK  FOR LEAKS 15. Check  for  leaks  as follows: a. Check  test setup  connections  upstream  and downstream  of  drain  valve  (3),  shutoff  valve (4),  and  gage  (14).   Use  mixture  of  soap (E353)  and  water,  and  brush  (E85).  Tighten connections  or  replace  packings  as  needed. Repeat  steps  13  and  14. 10-94