TM 55-1520-240-23-4
5-79
INSTALL LIGHTNING PROTECTION JUMPER WIRE INSERT
(Continued)
5-79
6.
Position two washers (6) and wire (7) over insert
(2). Install bolt (8) and washer (9). Torque bolt to
30 inch-pounds.
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7.
Apply sealant (E336) over wire terminal (10)
and wire (7) to clamp (11). Wear gloves (E186).
Allow sealant to cure at 70º - 80ºF (21º - 27ºC)
for 6 hours.
FOLLOW-ON MAINTENANCE:
None
END OF TASK