TM 55-1520-240-23-4
5-57
INSTALL CENTRIFUGAL DROOP STOP SPRINGS AND WEIGHTS
5-57
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 5 to 50 Inch-Pounds
Materials:
Epoxy Primer (E292)
Gloves (E184.1)
Parts:
Cotter Pins
Personnel Required:
Medium Helicopter Repairer (5)
Inspector
References:
TM 55-1520-240-23P
General Safety Instructions:
Do not lower blade suddenly.
Personnel can be injured if blade is
lowered suddenly while droop stop
work is in progress.
Epoxy primer (E292) is flammable
and toxic. It can irritate skin and
cause burns. Use only with adequate
ventilation, away from heat and open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
5-250