TM 55-1520-240-23-10
14-16
CLEAN AND INSPECT CABLE CUTTER
14-16
INITIAL SETUP
Applicable Configurations:
All
Tools:
None
Materials:
Cleaning Brush (E84)
Cloths (E135)
Dry Cleaning Solvent (E162)
Lubricating Oil (E250)
Powder Solvent (E464)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Inspector
Equipment Condition:
Off Helicopter Task
1.
Clean cartridge chamber (1). Use powder
solvent (E464) and cleaning brush (2) (E84).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
2.
Clean cable cutter (3) except chamber (1). Use
clean cloth (E135) wet with solvent (E162). Let
parts air dry. Wear gloves (E186).
14-49