TM 55-1520-240-23-9
11-98
INSTALL ROLL IDLER BELLCRANK
11-98
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 0 to 150 Inch-Pounds
Dial Indicating Scale, 0 to 10 Pounds
Materials:
Cleaning Cloth (E120)
Dry Cleaning Solvent (E162)
Epoxy Primer (E292)
Gloves (E184.1)
Parts:
Cotter Pins
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 1-1520-253-23
TM 55-1520-240-23P
Task 1-13
General Safety Instructions:
Epoxy primer (E292) is flammable
and toxic. It can irritate skin and
cause burns. Use only with adequate
ventilation, away from heat and
open flame. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Dry cleaning solvent (E162) is
combustible and toxic. Avoid contact
with skin, eyes, or clothing. Use
only with adequate ventilation, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
11-512