TM 55-1520-240-23-9
11-6.2
CHECK CONTROLS FOR OVERALL LOOSENESS
(Continued)
11-6.2
1.
Working from forward left work platform, attach
scale (1) to bolt (2) of forward left bellcrank (3).
2.
Have helper pull scale (1) down until scale
indicates 10 pounds. Measure distance A
between bolt (2) and top surface (4) of fitting (5).
3.
Have helper pull scale (1) up until scale indicates
10 pounds. Measure distance B between bolt
(2) and surface (4).
4.
Subtract distance A from distance B. Result
shall not be more than 0.375 inch. If more,
perform Tasks 11-7, 11-7.1, and 11-9, then
11-6.3.
5.
Remove scale (1) from bolts (2).
6.
Working from forward right work platform, attach
scale (1) to bolt (6) of forward right bellcrank (7).
7.
Have helper pull scale (1) down until scale
indicates 10 pounds. Measure distance C
between bolt (6) and forward surface (8) at sta.
120.00.
8.
Have helper pull scale (1) up until scale indicates
10 pounds. Measure distance D between bolt
(6) and surface (8).
9.
Subtract distance D from distance C. Result
shall not be more than 0.375 inch. If more,
perform Tasks 11-7, 11-7.1, and 11-9, then
11-6.3.
10.
Remove scale (1) from bolt (6).
INSPECT