TM 55-1520-240-23-9
11-277
BENCH TEST AFCS COMPUTER (AVIM)
(Continued)
11-277
65.
Set CIRCUIT SELECT A UNITS switch (18) to 3.
Read AC/DC VOLTMETER (10). Reading shall
be +6.5 to +7.5.
66.
Set CONTROL PANEL SIMULATION HEADING
switch (26) to DISENG.
67.
Set DISCRETE SIGNALS CYCLIC BRAKE
switch (27) to 1. Read AC/DC VOLTMETER (10).
Reading shall be -6.5 to -7.5.
68.
Set CIRCUIT SELECT A UNITS switch (18) to 2.
Read AC/DC VOLTMETER (10). Reading shall
be +6.5 to +7.5.
69.
Set DISCRETE SIGNAL CYCLIC BRAKE switch
(27) to 0.
70.
Set DISCRETE SIGNALS DETENT ROLL switch
(28) to 1. Read AC/DC VOLTMETER (10).
Reading shall be +6.5 to +7.5.
71.
Set DISCRETE SIGNALS DETENT ROLL switch
(28) to 0.
72.
Set ANALOG SIGNALS LAT CPT switch (29)
to 2.
73.
Set ANALOG SIGNALS ROLL RATE switch (30)
to 3. Read AC/DC VOLTMETER (10). Reading
shall be +6.5 to +7.5.
74.
Set ANALOG SIGNALS LAT CPT switch (29)
to 3. Read AC/DC VOLTMETER (10). Reading
shall be +6.5 to +7.5.
75.
Set ANALOG SIGNALS ROLL RATE switch (30)
to 2. Read AC/DC VOLTMETER (10). Reading
shall be -6.5 to -7.5.
76.
Set CIRCUIT SELECT A UNITS switch (18) to 4.
Read AC/DC VOLTMETER (10). Reading shall
be +6.5 to +7.5.