TM 55-1520-240-23-9
11-277
BENCH TEST AFCS COMPUTER (AVIM)
(Continued)
11-277
21.
Set CIRCUIT SELECT B UNITS switch (11) to 6.
Read AC/DC VOLTMETER (10). Reading shall
be +11.26 to +12.74.
22.
Set CIRCUIT SELECT B UNITS switch (11) to 7.
Read AC/DC VOLTMETER (10). Reading shall
be -11.26 to -12.74.
23.
Set METER switch (6) to AC.
24.
Set METER RANGE switch (7) to 200V.
25.
Set CIRCUIT SELECT B UNITS switch (11) to 8.
Read AC/DC VOLTMETER (10). Reading shall
be +24.58 to +27.42.
26.
Set METER RANGE switch (7) to 20V.
27.
Set CIRCUIT SELECT B UNITS switch (11) to 9.
Read AC/DC VOLTMETER (10). Reading shall
be +12.29 to +13.71.
28.
Set CIRCUIT SELECT B UNITS switch (11) to 0.
29.
Set CIRCUIT SELECT TENS switch (8) to 20.
Read AC/DC VOLTMETER. Reading shall be
+12.29 to +13.71.
30.
Set CIRCUIT SELECT TENS switch (8) to 00.
END POWER SUPPLY TEST
11-1075