TM 55-1520-240-23-9
11-277
BENCH TEST AFCS COMPUTER (AVIM)
(Continued)
11-277
123.
Set CIRCUIT SELECT A UNITS switch (18) to 8.
124.
Set RESPONSE TEST STIM switch (44) to
APPLY. When HOLD lamp (45) comes on, read
AC/DC VOLTMETER (10). Reading shall be
+1.94 to +2.74.
125.
Set RESPONSE TEST STIM switch (44) to
REMOVE.
126.
Set RESPONSE TEST TIME DELAY-SEC
switches (40) to 0.11.
127.
Set RESPONSE TEST STIM switch (44) to
APPLY. When HOLD lamp (45) comes on, read
AC/DC VOLTMETER (10). Reading shall be
+0.86 to +1.32.
128.
Set RESPONSE TEST STIM switch (44) to
REMOVE.
129.
Set ANALOG SIGNALS RESPONSE TEST
TIME DELAY-SEC switches (40) to 1.00.
130.
Set ANALOG SIGNALS PITCH ATT HSI HDG
pot. (42) to 500.
131.
Set ANALOG SIGNALS GND-SIGNAL switch
(41) to GND.
132.
Set ANALOG SIGNALS PITCH RATE switch
(46) to 2.
133.
Set CIRCUIT SELECT A UNITS switch (18) to 7.
134.
Set RESPONSE TEST STIM switch (44) to
APPLY. When HOLD lamp (45) comes on, read
AC/DC VOLTMETER (10). Reading shall be
+7.26 to +10.45.
11-1084