TM 55-1520-240-23-8
10-82
INSTALL AFT TANK FUEL LEVEL SHUTOFF VALVE
(Continued)
10-82
24.
Install packing (11) on flange of valve (2).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
25.
Remove tape and barrier material from hole in
tank (12). Clean tape residue from tank. Use dry
cleaning solvent (E162). Wear goggles to protect
eyes. Wear gloves (E186).
26.
Maneuver fuel valve (2) through hole in tank
(12), tube (1) pointing down. Remove tags and
connect two hoses (13) to valve connections (3).
27.
Position flange of valve (2) against tank (12),
tube (1) pointing down. Install ten bolts (14) and
washers (15).
28.
Remove plugs from adapter (16), elbow (17),
and tee (18).
29.
Position adapter (16) and elbow (17) on tee (18).
NOTE
Gaskets (20.1) are used with shutoff
valve pin AV16B2101D-1 only.
30.
Position three gaskets (20), two gaskets (20.1)
coated with sealant (E342.1), valve (21), and
spacer (22) on fitting (8).
31.
Slide adapter (16) aft. Secure adapter. Use eight
bolts (23), and washers (24). Tighten coupling
(26) and bolts.
32.
Connect electrical connector (27).
INSPECT
Go to Follow-On Maintenance.