TM 55-1520-240-23-8
10-66
INSTALL FORWARD OR AFT FUEL TANK VENT ASSEMBLY
(Continued)
10-66
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
NOTE
Procedure is same to install No. 1
and No. 2 forward or aft fuel tank vent
assembly. No. 1 (left) forward fuel
tank vent assembly is shown here.
1.
Remove barrier material and tape from forward
access hole (1).
2.
Remove tape residue from face of tank (2). Use
dry cleaning solvent (E162) and cloths (E135).
Wear goggles to protect eyes. Wear gloves
(E184.1).
3.
Position vent assembly (3) on two brackets (4).
Install four screws (5), washers (6), and nuts (7).
NOTE
If required, a stand off spacer tube
may be used to allow clearance
between the bracket and the control
valve. Tube length should be as
required.
4.
Position clamp (8). Install screw (9), washer (10),
and nut (11).
10-327