TM 55-1520-240-23-7
9-137
INSTALL PITCH AND ROLL CONTROL STICK GRIP
9-137
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Contact Insertion/Removal Tool, M83723-31-20
Materials:
Dry Cleaning Solvent (E162)
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Dry cleaning solvent (E162) is
combustible and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
1.
Install grommet (1) in tube (2).
2.
Install grip (3) on tube (2) while feeding wires
(4) through tube.
3.
Install screw (5) and washer (6) in grip (2).
Position screw through middle of wires (4).
4.
Slide backshell (7) over wires (4).
9-544