TM 55-1520-240-23-79-78TEST AND ADJUST LANDING LIGHT9-78INITIAL SETUPApplicable Configurations:AllTools:Electrical Repairer’s Tool Kit, NSN 5180-00-323-4915Power Switch, Two-PositionControl Switch, Five-PositionTerminal Board, Eight TerminalDC Power Supply, 25 AmpereMaterials:NonePersonnel Required:Aircraft Electrician (2)InspectorEquipment Condition:Off Helicopter TaskTest SetupGeneral Safety Instructions:Do not look into lighted NVG landinglight. Infra-red light output canseriously injure eyes.1.Connect test setup (1) to landing light (2).2.Turn on power supply (3). Adjust power supplyoutput to 28 vdc.3.Set power switch (4) to on. Check lamp (5).Lamp shall come on. Check visually without 17 .Check for heat output with 17 .4.Set power switch (4) to off. Check lamp (5).Lamp shall go off. Check visually without 17 .Check for heat output with 17 .5.Set control switch (6) to EXTEND. Check light(2). Light shall fully extend and stop.6.Measure length of spring (7). Record length.7.Set control switch (6) to RETRACT. Check light(2). Light shall fully retract and stop.9-263