TM 55-1520-240-23-7
9-48
INSTALL AC POWER RECEPTACLE
9-48
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
Acetone (E20)
Sealant (E336)
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
1.
Clean surfaces around hole (1) of box (2) and
receptacle (3). Use acetone (E20) and cloths
(E120). Wear gloves (E186).
2.
Remove six nuts (4), washers (5) and washers
(6) from terminals (7).
3.
Remove tape from ends of six wires (8). Connect
wires to terminals (7) of receptacle (3). Install
six washers (6), washers (5) and nuts (4) on
terminals. Remove tags from wires.
INSPECT
4.
Position receptacle (3), two small terminals (7)
up and forward, in hole (1) of box (2).
9-144