TM 55-1520-240-23-7
8-80.5.1
TEST AND ADJUST FUEL QUANTITY INDICATOR USING PSD 60-1AF FUEL QUANTITY
TEST SET
(Continued)
8-80.5.1
41.
Rotate FUNCT switch (S-2) on tester to
MEASURE INT.
42.
Adjust COMP SIM decade (D-2) to read "99"
(Figure 20).
43.
Adjust COMP SIM vernier (V-2) to read 1004.6
pf on tester LCD (Figure 21).
NOTE
This capacitance value equals four
AUX tanks at 850 lb each or a total of
3400 lb.
44.
Rotate SELECT switch (S-3) on tester to TU
position.
45.
Adjust TU decade (D-1) to "157" (Figure 22).
8-243