TM 55-1520-240-23-7
8-32
INSTALL SIDESLIP SENSING PORTS (Continued)
8-32
4.
Install six screws (5). Torque screws to 6
inch-pounds.
5.
Connect sideslip sensing line (6), at compression
fitting nut (7).
6.
Connect electrical connector (8).
FOLLOW-ON MAINTENANCE:
Leak check sideslip system (TM 55-1520-240-T).
Close nose enclosure access door (Task 2-2).
END OF TASK
8-110