TM 55-1520-240-23-7
8-34
INSTALL STATIC PORT ADAPTER
8-34
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Airframe Repairers Tool Kit, NSN 5180-00-323-4876
Workstand
Materials:
Dry Cleaning Solvent (E162)
Cloths (E120)
Gloves (E186)
Sealant (E336)
Parts:
Packing
Rivets
Personnel Required:
Medium Helicopter Repairer
Aircraft Structural Repairer
Inspector
References:
TM 1-1500-204-23
TM 55-1520-240-23P
TM 55-1520-240-T
Dry cleaning solvent (E162) is
combustible and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
NOTE
Procedure is same to install No. 1 or
No. 2 static ports. No. 1 static port is
shown here.
1.
Clean mating surfaces of static port adapter (1)
and inner fuselage skin (2). Use gloves (E186)
and dry cleaning solvent (E162). Make sure no
debris is in static port holes (3). Make sure holes
are not deformed.
8-113