REMOVE UTILITY COOLING FAN (Continued)
INSTALL UTILITY COOLING FAN (Continued)
TM-55-1520-240-23-6 CH-47D Heilcopter Manual
Page Navigation
839
840
841
842
843
844
845
846
847
848
849
TM 55-1520-240-23-6
7-223
INSTALL UTILITY COOLING FAN
7-223
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanic’s Tool Kit, NSN
5180-00-323-4692
Materials:
Lockwire (E231)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
1.
Position screen (1) on fan (2). Install four screws
(3) and washers (4).