TM 55-1520-240-23-6
7-187
REMOVE RETURN CONTROL MODULE
(Continued)
7-187
NOTE
If diaphragm must be removed, refer
to Task 7-349.
1.
Tag and disconnect three connectors (1) from
module (2).
2.
Tag and disconnect seven tubes (3) from module
(2). Use container and cloths (E135) for spilled
fluid. Use gloves (E186).
3.
Tag and disconnect two tubes (4) from module
(2). Use container and cloths (E135) for spilled
fluid.
4.
Have helper support module (2). Remove three
bolts (5) and washers (6). Remove module (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-757