TM 55-1520-240-23-6
7-185
REMOVE APU START MODULE
(Continued)
7-185
1.
Disconnect connector (1) from module (2).
2.
Tag and disconnect four tubes (3). Use container
and cloths (E135) for spilled fluid. Use gloves
(E186).
3.
Remove three bolts (4) and washers (5).
4.
Remove module (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-754