TM 55-1520-240-23-6
7-189
REMOVE UTILITY RETURN CONTROL MODULE TRANSFER CYLINDER
(Continued)
7-189
1.
Loosen standoff on tube (1). Disconnect tube (1)
from cylinder (2).
2.
Connect hose (3) from container (4) to port (5).
3.
Force piston (6) into cylinder (2). Push piston
or strike it with rubber mallet. Drain fluid into
container (4). Use gloves (E186).
4.
Remove hose (3) and container (4).
5.
Remove lockwire from two bolts (7).
6.
Have helper support cylinder (2). Remove two
bolts (7) and washers (8).
7.
Remove cylinder (2). Use cloths (E135) for
spilled fluid.
8.
Remove lockwire from valve (9).
9.
Remove valve (9) and packing (10) from port
(11).
10.
Remove two packings (12) from ports (13).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-761