TM 55-1520-240-23-6
7-160
REMOVE PRESSURE CONTROL MODULE PILOT VALVES
(Continued)
7-160
NOTE
Procedure is same to remove RH
ENG, LH ENG, or PTU pilot valves.
PTU valve is shown here.
1.
Disconnect connector (1) from valve (2).
2.
Remove lockwire from valve (2). Remove valve,
three packings (3), and four retainers (4) from
valve port (5). Use container and cloths (E135)
for spilled fluid. Use gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-688