TM 55-1520-240-23-67-160REMOVE PRESSURE CONTROL MODULE PILOT VALVES7-160INITIAL SETUPApplicable Configurations:AllTools:Aircraft Mechanic’s Tool Kit, NSN 5180-00-323-4692Crowfoot, 1 InchContainer, 2 QuartMaterials:Cloths (E135)Gloves (E186)Personnel Required:Medium Helicopter RepairerEquipment Condition:Battery Disconnected (Task 1-39)Electrical Power OffHydraulic Power OffUtility Hydraulic System Depressurized (Task 7-135.1)Cargo Ramp Open and Level (TM 55-1520-240-10)General Safety Instructions:Hydraulic fluid (E199) is toxic. It canirritate skin and cause burns. Avoidinhaling. Use only with adequateventilation. Avoid contact with skin,eyes, or clothing. In case of contact,immediately flush skin or eyes withwater for at least 15 minutes. Getmedical attention for eyes.Hydraulic fluid ejected under pressurecan cause injury to personnel.Hydraulic fluid sprayed into the air isa fire hazard.7-687