TM 55-1520-240-23-6
7-148.2
REPLACE APU START ACCUMULATOR MOUNTING PLATE
(Continued)
7-148.2
3.
Remove four bolts (5), four washers (6), and
mounting plate (2) from structure.
INSTALL PLATE
4.
Clean structure in the area of mounting plate (2).
Use cloths (E120).
5.
Install mounting plate (2), four washers (6), and
four bolts (5).
6.
Connect tee (4) to mounting plate (2). Tighten
nut (3).
7.
Connect tube (1) to mounting plate (2).
INSPECT
FOLLOW-ON MAINTENANCE:
Install APU start accumulator (Task 7-149).
END OF TASK
7-663