TM 55-1520-240-23-6
7-123.2
CHECK PIVOTING AND SWIVELING SERVOCYLINDER CONTROL VALVES FOR
LEAKAGE
7-123.2
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Workstand
Strap Tool (MS90387)
Materials:
Cloths (E135)
Gloves (E186)
Parts:
Straps (E375)
Personnel Required.:
Aircraft Pneudraulics Repairer (2)
Inspector
References:
TM 55-1520-240-23P
Equipment Condition:
Battery Connected (Task 1-39)
Electrical Power On
Hydraulic Power On
Forward and Aft Work Platforms Open (Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
Keep head, hands and other body
parts clear of moving flight controls.
Hydraulic forces can cause severe
injury.
7-546