TM 55-1520-240-23-6
7-114
DISASSEMBLE AND INSPECT FLIGHT CONTROL RESERVOIR/COOLER (AVIM)
7-114
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Container, 2 Quart
Deep Socket, 7/16 Inch
Technical Inspection Tool Kit, NSN 5180-00-323-5114
Outside Micrometer Caliper, 1 to 2 Inch
Materials:
Cloths (E120)
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
TM 1-1520-253-23
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-519