TM  55-1520-240-23-6
7-104.2
TEST ILCA  JAM  SENSORS   PHASE  II
(Continued)
7-104.2
NOTE
This task  is to  be  followed  if  suspect
ILCA  fails  PHASE  I  TEST  (Task
7-104.1)  and  no  replacement ILCA  is
available  or field  requirements do  not
allow for immediate  replacement.
1.
Set FLT  CONTR  switch  (1)  to  BOTH.
2.
Set AFCS  SYSTEM  SEL  switch  (3)  to  OFF.
3.
DEPRESS  and  HOLD centering  device  release
switch  (4) on  cyclic stick (2) while  inspecting  the
suspect roll, pitch  or yaw ILCAs as follows.
4.
Grasp  input control  rod  (5)  to  the  suspect ILCA
and  move  it  up  and  down.
5.
Observe  that  the  control  valve  lever  on  the  side
of  the  ILCA  housing  moves freely  between  the
machined  mechanical  stops.
NOTE
Motion  must  exhibit  NO  binding  and
POSITIVELY  contact  the  mechanical
stops  by solid  feel.  If  condition  exists,
proceed  to  step  10  and  perform
remaining  task  steps.
6.
Release  the  centering  device  release  switch  (4)
on  the  cyclic  stick (2).
7-497