TM 55-1520-240-23-6
7-104
INSTALL LOWER CONTROLS ACTUATOR STRUCTURAL MANIFOLD
(Continued)
7-104
NOTE
There are six tubes. Three connected
to top and three connected to bottom
of manifold.
3.
Connect tube (9) to fitting (10).
4.
Connect tube (11) to fitting (12).
5.
Connect tube (13) to fitting (14).
6.
Connect tube (15) to fitting (16).
7.
Connect tube (17) to fitting (18).
8.
Connect tube (19) to fitting (20).
9.
Torque tubes (9, 11, 13 and 16) to 140
inch-pounds.
10.
Torque tubes (17 and 19) to 170 inch-pounds.
INSPECT
FOLLOW-ON MAINTENANCE:
Install integrated lower control actuator (ILCA) (Task
7-102).
Bleed flight control hydraulic system (Task 7-16).
Perform operational check (TM 55-1520-240-T).
Install controls closet panel (Task 2-2).
Install controls closet acoustic blanket (Task 2-108).
END OF TASK
7-492