TM 55-1520-240-23-6
7-5
REPAIR PERMASWAGE PLUMBING
7-5
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Permaswage Tube Repair Kit, D1202C-15-H10, NSN
5180-01-115-7008
Portable Hydraulic Power Supply
Materials:
Hydraulic Fluid (E199)
Gloves (E184.1)
Marking Pen (E271.2)
Parts:
Hydraulic Tube and Fittings, As Required
Personnel Required:
Aircraft Pneudraulics Repairer
References:
TM 55-1520-240-23P
Equipment Condition:
Applicable System Drained
Hydraulic Line to be Repaired Disconnected from
Structure
Applicable Work Platforms or Access Panels Open
(Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-27