TM 55-1520-240-23-6
7-85
REMOVE EXTENSIBLE LINK
(Continued)
7-85
NOTE
Procedure is same to remove No. 1 or
No. 2 extensible link on roll, pitch, or
yaw integrated lower control actuator
(ILCA). Removal of No. 2 extensible
link is shown here.
1.
Remove strap (1) from receptacle (2).
2.
Disconnect plug (3) from receptacle (4).
3.
Remove lockwire from screw (5). Remove screw
from clip (6).
4.
Remove tywrap (7) and grommet (8) from
pressure tube (9).
5.
Pull pressure tube (9) and remove from manifold
(10).
6.
Remove packing (11) from pressure tube (9).
7.
Remove cotter pin (12), nut (13), and bolt (15)
from link (16).
8.
Remove lockwire from three bolts (17).
9.
Remove three bolts (17) from extensible link (18).
10.
Remove extensible link (18) and transfer tube
(19) from manifold (10). Use cloths (E135) for
spilled fluid. Wear gloves (E186).
11.
Remove lockwire from transfer tube (19).
Remove tube.
12.
Remove packings (20) from transfer tube (19).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-341