TM 55-1520-240-23-6
7-42
INSTALL NO. 1 OR NO. 2 POWER CONTROL MODULE THREE WAY VALVE
7-42
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 100 to 750 Inch-Pounds
Container, 2 Quart
Materials:
Lockwire (E230)
Hydraulic Fluid (E199)
Gloves (E184.1)
Parts:
None
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
Task 7-42.1
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-212