TM 55-1520-240-23-6
7-28
INSTALL NO.2 FLIGHT CONTROL HYDRAULIC PUMP
(Continued)
7-28
13.
Connect hose (23) to IN port (5). Remove tag.
Use cloths (E120) for spilled fluid.
14.
Connect hose (24) to OUT port (9). Remove tag.
Use cloths (E120) for spilled fluid.
15.
Deleted.
16.
Connect hose (26) to case drain port (19).
Remove tag. Use cloths (E120) for spilled fluid.
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed flight control hydraulic system (Task 7-16).
Perform operational check of flight control system
(TM 55-1520-240-T).
Close left transmission access door (Task 2-2)
Close cargo ramp (TM 55-1520-240-T).
END OF TASK