INSTALL NO. 1 FLIGHT CONTROL HYDRAULIC PUMP
(Continued)
7-27
11.1.
Remove cap (2) from IN port (5).
12.
Connect hose (23) to IN port (5). Remove tag.
Use cloths (E120) for spilled fluid.
13.
Remove cap (2) from OUT port (9).
14.
Connect hose (24) to OUT port (9). Remove tag.
Use cloths (E120) for spilled fluid.
15.
Remove cap (2) from SD port (14).
16.
Connect hose (25) to SD port (14). Remove tag.
Use cloths (E120) for spilled fluid.
17.
Remove cap (2) from case drain port (17).
18.
Connect hose (26) to case drain port (17).
Remove tag. Use cloths (E120) for spilled fluid.
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed flight control hydraulic system (Task 7-16).
Perform operational check (TM 55-1520-240-T).
Install forward transmission drip pan (Task 2-3).
END OF TASK