TM 55-1520-240-23-6
7-28
INSTALL NO.2 FLIGHT CONTROL HYDRAULIC PUMP
(Continued)
7-28
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7.
Clean spline (19). Use solvent (E162). Use
cloths for spilled fluid. Wear gloves (E184.1).
8.
Coat spline (19) and packing (19.1) with grease
(E190). Install packing (19.1) on spline.
8.1.
Install gasket (19.2) on pump (1).
9.
Remove protective material from pump
transmission mount.
NOTE
When installing a Stratopower/
Dynapower pump there is a metal
shim bonded to pump flange. If this
shim comes unbonded from the
pump flange. It does not have to be
rebonded for installation.
10.
Position pump (16) over four studs (20) with IN
port (5) up. Rotate pump clockwise.
11.
Connect hose (21) to union (15) of drain port
(17).
Oil (E254 or E254.1) are toxic.
They can irritate skin and cause
burns. Avoid inhaling. Use only with
adequate ventilation. Avoid contact
with skin, eyes, or clothing. In case
of contact, immediately flush skin
or eyes with water for at least 15
minutes. Get medical attention for
eyes.
12.
Install four nuts (22). Torque nuts wet with oil
(E254 or E254.1) to 70 to 100 inch-pounds.
NOTE
Torque on nuts (22) must be checked
for 85 inch-pounds after the first
flight. Do not back nuts off before
torquing.
7-172