TM 55-1520-240-23-6
7-21
INSTALL FILL MODULE
(Continued)
7-21
2.
Position module (4) on bracket (5). Install bolt (6)
and washer (7) through pump (8).
3.
Install two bolts (9) and washers (10) through
bracket (5).
4.
Torque bolts (6 and 9) to 40 inch-pounds.
5.
Connect three tubes (11) to unions (2). Use
cloths (E120) for spilled fluids.
6.
Tighten nuts (12).
INSPECT
7.
Install screw (13) in two clamps (14).
8.
Rotate valve handle (15) clockwise back to FILL
position.
FOLLOW-ON MAINTENANCE:
Bleed flight control hydraulic system (Task 7-16).
Perform operational check of utility hydraulic system
(TM 55-1520-240-T).
Perform operational check of flight control hydraulic
system (TM 55-1520-240-T).
Close cargo ramp (TM 55-1520-240-T).
END OF TASK
7-153