FLUSH WHEEL BRAKE PRESSURE TUBING
(Continued)
7-322
44.
Working at aft landing gear, connect hose (46)
to hose (53).
45.
Connect hose (46) to hose (49).
Do not exceed 500 psi. Otherwise
damage to components can occur.
Keep test stand bypass valve closed.
Otherwise, contaminants could
re-enter the system.
46.
Apply hydraulic power. Set stand to 10 gpm at
500 psi. Flush system for 15 minutes. Check
for leaks.
47.
Remove hydraulic power.
48.
Disconnect hose (46) from hose (53) and hose
(49). Use container and cloths (E120) for spilled
fluid. Use gloves (E186).
49.
Connect hose (53) to port (54).
50.
Connect hose (49) to port (50).