TM 55-1520-240-23-6
7-15
FLUSHING EXTERNAL POWER SUPPLY LINES FLIGHT CONTROL HYDRAULIC
SYSTEM
7-15
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5780-0-323-4891
Container
Hydraulic Test Stand
Filter Assembly Kit ADHT6814-M9716M
Materials:
Hydraulic Fluid (E199)
Cloths (E120)
Gloves (E186)
Parts:
Test Hoses
Fittings
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
No. 1 Power Control Module Removed (Task 7-29)
No. 2 Power Control Module Removed (Task 7-31)
Pylon Access Door Open (Task 2-2)
Forward Work Platforms Open (Task 2-2)
Hydraulic Connection Access Panel Open (Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-92